| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2020-27297 | 1 Honeywell | 1 Opc Ua Tunneller | 2024-11-21 | 9.8 Critical |
| The affected product is vulnerable to a heap-based buffer overflow, which may allow an attacker to manipulate memory with controlled values and remotely execute code on the OPC UA Tunneller (versions prior to 6.3.0.8233). | ||||
| CVE-2020-27288 | 1 Deltaww | 1 Tpeditor | 2024-11-21 | 7.8 High |
| An untrusted pointer dereference has been identified in the way TPEditor(v1.98 and prior) processes project files, allowing an attacker to craft a special project file that may permit arbitrary code execution. | ||||
| CVE-2020-27287 | 1 Deltaww | 1 Cncsoft-b | 2024-11-21 | 7.8 High |
| Delta Electronics CNCSoft-B Versions 1.0.0.2 and prior is vulnerable to an out-of-bounds write while processing project files, which may allow an attacker to execute arbitrary code. | ||||
| CVE-2020-27284 | 1 Deltaww | 1 Tpeditor | 2024-11-21 | 7.8 High |
| TPEditor (v1.98 and prior) is vulnerable to two out-of-bounds write instances in the way it processes project files, allowing an attacker to craft a special project file that may permit arbitrary code execution. | ||||
| CVE-2020-27281 | 1 Deltaww | 1 Cncsoft Screeneditor | 2024-11-21 | 7.8 High |
| A stack-based buffer overflow may exist in Delta Electronics CNCSoft ScreenEditor versions 1.01.26 and prior when processing specially crafted project files, which may allow an attacker to execute arbitrary code. | ||||
| CVE-2020-27278 | 1 Hamilton-medical | 2 Hamilton-t1, Hamilton-t1 Firmware | 2024-11-21 | 5.2 Medium |
| In Hamilton Medical AG,T1-Ventillator versions 2.2.3 and prior, hard-coded credentials in the ventilator allow attackers with physical access to obtain admin privileges for the device’s configuration interface. | ||||
| CVE-2020-27275 | 1 Deltaww | 1 Dopsoft | 2024-11-21 | 7.8 High |
| Delta Electronics DOPSoft Version 4.0.8.21 and prior is vulnerable to an out-of-bounds write while processing project files, which may allow an attacker to execute arbitrary code. | ||||
| CVE-2020-27274 | 1 Honeywell | 1 Opc Ua Tunneller | 2024-11-21 | 7.5 High |
| Some parsing functions in the affected product do not check the return value of malloc and the thread handling the message is forced to close, which may lead to a denial-of-service condition on the OPC UA Tunneller (versions prior to 6.3.0.8233). | ||||
| CVE-2020-27267 | 4 Ge, Ptc, Rockwellautomation and 1 more | 7 Industrial Gateway Server, Kepware Kepserverex, Opc-aggregator and 4 more | 2024-11-21 | 9.1 Critical |
| KEPServerEX v6.0 to v6.9, ThingWorx Kepware Server v6.8 and v6.9, ThingWorx Industrial Connectivity (all versions), OPC-Aggregator (all versions), Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server v7.68.804 and v7.66, and Software Toolbox TOP Server all 6.x versions, are vulnerable to a heap-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and potentially leak data. | ||||
| CVE-2020-27265 | 4 Ge, Ptc, Rockwellautomation and 1 more | 7 Industrial Gateway Server, Kepware Kepserverex, Opc-aggregator and 4 more | 2024-11-21 | 9.8 Critical |
| KEPServerEX: v6.0 to v6.9, ThingWorx Kepware Server: v6.8 and v6.9, ThingWorx Industrial Connectivity: All versions, OPC-Aggregator: All versions, Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server: v7.68.804 and v7.66, Software Toolbox TOP Server: All 6.x versions are vulnerable to a stack-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and remotely execute code. | ||||
| CVE-2020-27263 | 4 Ge, Ptc, Rockwellautomation and 1 more | 7 Industrial Gateway Server, Kepware Kepserverex, Opc-aggregator and 4 more | 2024-11-21 | 9.1 Critical |
| KEPServerEX: v6.0 to v6.9, ThingWorx Kepware Server: v6.8 and v6.9, ThingWorx Industrial Connectivity: All versions, OPC-Aggregator: All versions, Rockwell Automation KEPServer Enterprise, GE Digital Industrial Gateway Server: v7.68.804 and v7.66, Software Toolbox TOP Server: All 6.x versions, are vulnerable to a heap-based buffer overflow. Opening a specifically crafted OPC UA message could allow an attacker to crash the server and potentially leak data. | ||||
| CVE-2020-27262 | 1 Innokasmedical | 2 Vital Signs Monitor Vc150, Vital Signs Monitor Vc150 Firmware | 2024-11-21 | 5.4 Medium |
| Innokas Yhtymä Oy Vital Signs Monitor VC150 prior to Version 1.7.15 A stored cross-site scripting (XSS) vulnerability exists in the affected products that allow an attacker to inject arbitrary web script or HTML via the filename parameter to multiple update endpoints of the administrative web interface. | ||||
| CVE-2020-27261 | 1 Omron | 4 Cx-one, Cx-position, Cx-protocol and 1 more | 2024-11-21 | 8.8 High |
| The Omron CX-One Version 4.60 and prior is vulnerable to a stack-based buffer overflow, which may allow an attacker to remotely execute arbitrary code. | ||||
| CVE-2020-27260 | 1 Innokasmedical | 2 Vital Signs Monitor Vc150, Vital Signs Monitor Vc150 Firmware | 2024-11-21 | 5.3 Medium |
| Innokas Yhtymä Oy Vital Signs Monitor VC150 prior to Version 1.7.15 HL7 v2.x injection vulnerabilities exist in the affected products that allow physically proximate attackers with a connected barcode reader to inject HL7 v2.x segments into specific HL7 v2.x messages via multiple expected parameters. | ||||
| CVE-2020-27256 | 1 Sooil | 6 Anydana-a, Anydana-a Firmware, Anydana-i and 3 more | 2024-11-21 | 6.8 Medium |
| In SOOIL Developments Co., Ltd Diabecare RS, AnyDana-i and AnyDana-A, a hard-coded physician PIN in the physician menu of the insulin pump allows attackers with physical access to change insulin therapy settings. | ||||
| CVE-2020-27250 | 1 Softmaker | 1 Planmaker 2021 | 2024-11-21 | 7.8 High |
| In SoftMaker Software GmbH SoftMaker Office PlanMaker 2021 (Revision 1014), a specially crafted document can cause the document parser to copy data from a particular record type into a static-sized buffer within an object that is smaller than the size used for the copy, which will cause a heap-based buffer overflow at Version/Instance 0x0005 and 0x0016. An attacker can entice the victim to open a document to trigger this vulnerability. | ||||
| CVE-2020-27249 | 1 Softmaker | 1 Planmaker 2021 | 2024-11-21 | 7.8 High |
| A specially crafted document can cause the document parser to copy data from a particular record type into a static-sized buffer within an object that is smaller than the size used for the copy, which will cause a heap-based buffer overflow. In version/Instance 0x0004 and 0x0015, an attacker can entice the victim to open a document to trigger this vulnerability. This affects SoftMaker Software GmbH SoftMaker Office PlanMaker 2021 (Revision 1014). | ||||
| CVE-2020-27248 | 1 Softmaker | 1 Planmaker 2021 | 2024-11-21 | 7.8 High |
| A specially crafted document can cause the document parser to copy data from a particular record type into a static-sized buffer within an object that is smaller than the size used for the copy, which will cause a heap-based buffer overflow. In version/Instance 0x0003 and 0x0014, an attacker can entice the victim to open a document to trigger this vulnerability. This affects SoftMaker Software GmbH SoftMaker Office PlanMaker 2021 (Revision 1014). | ||||
| CVE-2020-27247 | 1 Softmaker | 1 Planmaker 2021 | 2024-11-21 | 7.8 High |
| A specially crafted document can cause the document parser to copy data from a particular record type into a static-sized buffer within an object that is smaller than the size used for the copy, which will cause a heap-based buffer overflow. In version/Instance 0x0002, an attacker can entice the victim to open a document to trigger this vulnerability. This affects SoftMaker Software GmbH SoftMaker Office PlanMaker 2021 (Revision 1014). | ||||
| CVE-2020-27227 | 1 Openclinic Ga Project | 1 Openclinic Ga | 2024-11-21 | 9.8 Critical |
| An exploitable unatuhenticated command injection exists in the OpenClinic GA 5.173.3. Specially crafted web requests can cause commands to be executed on the server. An attacker can send a web request with parameters containing specific parameter to trigger this vulnerability, potentially allowing exfiltration of the database, user credentials and compromise underlying operating system. | ||||