Export limit exceeded: 431860 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Export limit exceeded: 96665 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (96665 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2024-4494 | 1 Tenda | 2 I21, I21 Firmware | 2025-01-27 | 8.8 High |
| A vulnerability has been found in Tenda i21 1.0.0.14(4656) and classified as critical. Affected by this vulnerability is the function formSetUplinkInfo of the file /goform/setUplinkInfo. The manipulation of the argument pingHostIp2 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-263083. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
| CVE-2024-4495 | 1 Tenda | 2 I21, I21 Firmware | 2025-01-27 | 8.8 High |
| A vulnerability was found in Tenda i21 1.0.0.14(4656) and classified as critical. Affected by this issue is the function formWifiMacFilterGet. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-263084. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
| CVE-2024-4496 | 1 Tenda | 2 I21, I21 Firmware | 2025-01-27 | 8.8 High |
| A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been classified as critical. This affects the function formWifiMacFilterSet. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-263085 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
| CVE-2023-1732 | 1 Cloudflare | 1 Circl | 2025-01-27 | 5.3 Medium |
| When sampling randomness for a shared secret, the implementation of Kyber and FrodoKEM, did not check whether crypto/rand.Read() returns an error. In rare deployment cases (error thrown by the Read() function), this could lead to a predictable shared secret. The tkn20 and blindrsa components did not check whether enough randomness was returned from the user provided randomness source. Typically the user provides crypto/rand.Reader, which in the vast majority of cases will always return the right number random bytes. In the cases where it does not, or the user provides a source that does not, the blinding for blindrsa is weak and integrity of the plaintext is not ensured in tkn20. | ||||
| CVE-2024-28781 | 1 Ibm | 2 Devops Deploy, Urbancode Deploy | 2025-01-27 | 5.4 Medium |
| IBM UrbanCode Deploy (UCD) 7.0 through 7.0.5.20, 7.1 through 7.1.2.16, 7.2 through 7.2.3.9, 7.3 through 7.3.2.4, and 8.0 through 8.0.0.1 is vulnerable to cross-site scripting. This vulnerability allows users to embed arbitrary JavaScript code in the Web UI thus altering the intended functionality potentially leading to credentials disclosure within a trusted session. IBM X-Force ID: 285654. | ||||
| CVE-2024-4237 | 1 Tenda | 2 Ax1806, Ax1806 Firmware | 2025-01-27 | 8.8 High |
| A vulnerability, which was classified as critical, was found in Tenda AX1806 1.0.0.1. Affected is the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-262128. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
| CVE-2024-4238 | 1 Tenda | 2 Ax1806, Ax1806 Firmware | 2025-01-27 | 8.8 High |
| A vulnerability has been found in Tenda AX1806 1.0.0.1 and classified as critical. Affected by this vulnerability is the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-262129 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
| CVE-2024-4239 | 1 Tenda | 2 Ax1806, Ax1806 Firmware | 2025-01-27 | 8.8 High |
| A vulnerability was found in Tenda AX1806 1.0.0.1 and classified as critical. Affected by this issue is the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-262130 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
| CVE-2024-4240 | 1 Tenda | 2 W9, W9 Firmware | 2025-01-27 | 8.8 High |
| A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been classified as critical. This affects the function formQosManageDouble_user. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The associated identifier of this vulnerability is VDB-262131. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
| CVE-2024-4241 | 1 Tenda | 2 W9, W9 Firmware | 2025-01-27 | 8.8 High |
| A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been declared as critical. This vulnerability affects the function formQosManageDouble_auto. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack can be initiated remotely. The identifier of this vulnerability is VDB-262132. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
| CVE-2024-4242 | 1 Tenda | 2 W9, W9 Firmware | 2025-01-27 | 8.8 High |
| A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been rated as critical. This issue affects the function formwrlSSIDget of the file /goform/wifiSSIDget. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-262133 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
| CVE-2024-4243 | 1 Tenda | 2 W9, W9 Firmware | 2025-01-27 | 8.8 High |
| A vulnerability classified as critical has been found in Tenda W9 1.0.0.7(4456). Affected is the function formwrlSSIDset of the file /goform/wifiSSIDset. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-262134 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
| CVE-2024-4244 | 1 Tenda | 2 W9, W9 Firmware | 2025-01-27 | 8.8 High |
| A vulnerability classified as critical was found in Tenda W9 1.0.0.7(4456). Affected by this vulnerability is the function fromDhcpSetSer of the file /goform/DhcpSetSer. The manipulation of the argument dhcpStartIp/dhcpEndIp/dhcpGw/dhcpMask/dhcpLeaseTime/dhcpDns1/dhcpDns2 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-262135. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
| CVE-2024-4245 | 1 Tenda | 2 I21, I21 Firmware | 2025-01-27 | 8.8 High |
| A vulnerability, which was classified as critical, has been found in Tenda i21 1.0.0.14(4656). Affected by this issue is the function formQosManageDouble_user. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack may be launched remotely. The identifier of this vulnerability is VDB-262136. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
| CVE-2024-4246 | 1 Tenda | 2 I21, I21 Firmware | 2025-01-27 | 8.8 High |
| A vulnerability, which was classified as critical, was found in Tenda i21 1.0.0.14(4656). This affects the function formQosManageDouble_auto. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The identifier VDB-262137 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
| CVE-2024-4497 | 1 Tenda | 2 I21, I21 Firmware | 2025-01-27 | 8.8 High |
| A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been declared as critical. This vulnerability affects the function formexeCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-263086 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
| CVE-2024-4247 | 1 Tenda | 2 I21, I21 Firmware | 2025-01-27 | 8.8 High |
| A vulnerability has been found in Tenda i21 1.0.0.14(4656) and classified as critical. This vulnerability affects the function formQosManage_auto. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack can be initiated remotely. VDB-262138 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
| CVE-2024-4252 | 1 Tenda | 2 I22, I22 Firmware | 2025-01-27 | 8.8 High |
| A vulnerability classified as critical has been found in Tenda i22 1.0.0.3(4687). This affects the function formSetUrlFilterRule. The manipulation of the argument groupIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The associated identifier of this vulnerability is VDB-262143. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
| CVE-2024-4248 | 1 Tenda | 2 I21, I21 Firmware | 2025-01-27 | 8.8 High |
| A vulnerability was found in Tenda i21 1.0.0.14(4656) and classified as critical. This issue affects the function formQosManage_user. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack may be initiated remotely. The associated identifier of this vulnerability is VDB-262139. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||
| CVE-2024-4249 | 1 Tenda | 2 I21, I21 Firmware | 2025-01-27 | 8.8 High |
| A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been classified as critical. Affected is the function formwrlSSIDget of the file /goform/wifiSSIDget. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-262140. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. | ||||