| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Multiple untrusted search path vulnerabilities in the installer in Synology Cloud Station Backup before 4.2.5-4396 on Windows allow local attackers to execute arbitrary code and conduct DLL hijacking attacks via a Trojan horse (1) shfolder.dll, (2) ntmarta.dll, (3) secur32.dll or (4) dwmapi.dll file in the current working directory. |
| Multiple untrusted search path vulnerabilities in the installer in Synology Cloud Station Drive before 4.2.5-4396 on Windows allow local attackers to execute arbitrary code and conduct DLL hijacking attacks via a Trojan horse (1) shfolder.dll, (2) ntmarta.dll, (3) secur32.dll or (4) dwmapi.dll file in the current working directory. |
| Multiple untrusted search path vulnerabilities in installer in Synology Photo Station Uploader before 1.4.2-084 on Windows allows local attackers to execute arbitrary code and conduct DLL hijacking attack via a Trojan horse (1) shfolder.dll, (2) ntmarta.dll, (3) secur32.dll or (4) dwmapi.dll file in the current working directory. |
| Untrusted search path vulnerability in the installer of SaAT Netizen ver.1.2.10.510 and earlier allows an attacker to gain privileges via a Trojan horse DLL in an unspecified directory. |
| Untrusted search path vulnerability in the installer of Tera Term 4.94 and earlier allows an attacker to gain privileges via a Trojan horse DLL in an unspecified directory. |
| Untrusted search path vulnerability in RW-5100 tool to verify execution environment for Windows 7 version 1.1.0.0 and RW-5100 tool to verify execution environment for Windows 8.1 version 1.2.0.0 allows an attacker to gain privileges via a Trojan horse DLL in an unspecified directory. |
| A DLL Hijacking issue was discovered in Schneider Electric Interactive Graphical SCADA System (IGSS) Software, Version 12 and previous versions. The software will execute a malicious file if it is named the same as a legitimate file and placed in a location that is earlier in the search path. |
| Untrusted search path vulnerability in Installer of Shogyo Touki Denshi Ninsho Software Ver 1.7 and earlier allows an attacker to gain privileges via a Trojan horse DLL in an unspecified directory. |
| Untrusted search path vulnerability in Installer of electronic tendering and bid opening system available prior to May 25, 2017 allows an attacker to gain privileges via a Trojan horse DLL in an unspecified directory. |
| An Uncontrolled Search Path Element issue was discovered in Solar Controls Heating Control Downloader (HCDownloader) Version 1.0.1.15 and prior. An uncontrolled search path element has been identified, which could allow an attacker to execute arbitrary code on a target system using a malicious DLL file. |
| An Unquoted Search Path or Element issue was discovered in Automated Logic Corporation (ALC) ALC WebCTRL, i-Vu, SiteScan Web 6.5 and prior; ALC WebCTRL, SiteScan Web 6.1 and prior; ALC WebCTRL, i-Vu 6.0 and prior; ALC WebCTRL, i-Vu, SiteScan Web 5.5 and prior; and ALC WebCTRL, i-Vu, SiteScan Web 5.2 and prior. An unquoted search path vulnerability may allow a non-privileged local attacker to change files in the installation directory and execute arbitrary code with elevated privileges. |
| Untrusted search path vulnerability in Installer of Denshinouhin Check System (for Ministry of Agriculture, Forestry and Fisheries Nouson Seibi Jigyou) 2014 March Edition (Ver.9.0.001.001) [Updated on 2017 June 9], (Ver.8.0.001.001) [Updated on 2016 May 31] and earlier allows an attacker to gain privileges via a Trojan horse DLL in an unspecified directory. |
| Untrusted search path vulnerability in RW-4040 driver installer for Windows 7 version 2.27 allows an attacker to gain privileges via a Trojan horse DLL in an unspecified directory. |
| There exists a path traversal vulnerability in the Android Google Search app. This is caused by the incorrect usage of uri.getLastPathSegment. A symbolic encoded string can bypass the path logic to get access to unintended directories. An attacker can manipulate paths that could lead to code execution on the device. We recommend upgrading beyond version 13.41 |
| An unauthenticated user can access Identity Manager’s management console specific page URLs. However, the system doesn’t allow the user to carry out server side tasks without a valid web session. |
| The tested version of Dominion Voting Systems ImageCast X allows for rebooting into Android Safe Mode, which allows an attacker to directly access the operating system. An attacker could leverage this vulnerability to escalate privileges on a device and/or install malicious code. |
| Missing DLLs, if replaced by an insider, could allow an attacker to achieve local privilege escalation on the DeltaV Distributed Control System Controllers and Workstations (All versions) when some DeltaV services are started. |
| AVEVA Software Platform Common Services (PCS) Portal versions 4.5.2, 4.5.1, 4.5.0, and 4.4.6 are vulnerable to DLL hijacking through an uncontrolled search path element, which may allow an attacker control to one or more locations in the search path. |
| DWG TrueViewTM 2023 version has a DLL Search Order Hijacking vulnerability. Successful exploitation by a malicious attacker could result in remote code execution on the target system. |
| Multiple Mitsubishi Electric Factory Automation engineering software products have a malicious code execution vulnerability. A malicious attacker could use this vulnerability to obtain information, modify information, and cause a denial-of-service condition. |