| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| An application "com.pri.applock", which is pre-loaded on Kruger&Matz smartphones, allows a user to encrypt any application using user-provided PIN code or by using biometric data.
Exposed ”com.pri.applock.LockUI“ activity allows any other malicious application, with no granted Android system permissions, to inject an arbitrary intent with system-level privileges to a protected application. One must know the protecting PIN number (it might be revealed by exploiting CVE-2024-13916) or ask the user to provide it.
Only version (version name: 13, version code: 33) was tested and confirmed to have this vulnerability.
Application update was released in April 2025. |
| An application "com.pri.applock", which is pre-loaded on Kruger&Matz smartphones, allows a user to encrypt any application using user-provided PIN code or by using biometric data.
Exposed ”com.android.providers.settings.fingerprint.PriFpShareProvider“ content provider's public method query() allows any other malicious application, without any granted Android system permissions, to exfiltrate the PIN code.
Only version (version name: 13, version code: 33) was tested and confirmed to have this vulnerability.
Application update was released in April 2025. |
| Android based smartphones from vendors such as Ulefone and Krüger&Matz contain "com.pri.factorytest" application preloaded onto devices during manufacturing process.
The application "com.pri.factorytest" (version name: 1.0, version code: 1) exposes a ”com.pri.factorytest.emmc.FactoryResetService“ service allowing any application to perform a factory reset of the device.
Application update did not increment the APK version. Instead, it was bundled in OS builds released later than December 2024 (Ulefone) and April 2025 (Krüger&Matz). |
| A vulnerability was found in Euro Information CIC banque et compte en ligne App 12.56.0 on Android. Affected by this vulnerability is an unknown functionality of the file AndroidManifest.xml of the component com.cic_prod.bad. The manipulation leads to improper export of android application components. It is possible to launch the attack on the local host. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| Insecure Storage of Sensitive Information vulnerability in Calix GigaCenter ONT (Quantenna SoC modules) allows admin access to the web interface.This issue affects GigaCenter ONT: 844E, 844G, 844GE, 854GE. |
| Improper conditions check in some Intel(R) BIOS Guard firmware may allow a privileged user to potentially enable escalation of privilege via local access. |
| Improper conditions check in some Intel(R) BIOS PPAM firmware may allow a privileged user to potentially enable escalation of privilege via local access. |
| Information Disclosure in API in Replicated Replicated Classic versions prior to 2.53.1 on all platforms allows authenticated users with Admin Console access to retrieve sensitive data, including application secrets, via accessing container definitions with environment variables through the Admin Console API on port 8800.
This CVE was originally reserved in 2021 and later publicly disclosed by Replicated on their website on 21 October 2021. However, it mistakenly remained in the Reserved But Public (RBP) status with the CVE Numbering Authority (CNA). Please note that this product reached its end of life on 31 December 2024. Publishing this CVE with the CNA was required to comply with CNA rules, despite the fact that the issue was disclosed and fixed four years ago, and the affected product is no longer supported as of 2024.
Summary of VulnerabilityThis advisory discloses a low severity security vulnerability in the versions of Replicated Classic listed above (“Affected Replicated Classic Versions”)
DescriptionReplicated Classic versions prior to 2.53.1 have an authenticated API from the Replicated Admin Console that may expose sensitive data including application secrets, depending on how the application manifests are written. A user with valid credentials and access to the Admin Console port (8800) on the Replicated Classic server can retrieve container definitions including environment variables which may contain passwords and other secrets depending on how the application is configured.
This data is shared over authenticated sessions to the Admin Console only, and was never displayed or used in the application processing. To remediate this issue, we removed the sensitive data from the API, sending only the data to the Admin Console that was needed.
TimelineThis issue was discovered during a security review on 16 September 2021.
Patched versions were released on 23 September 2021.
This advisory was published on 21 October 2021.
The CVE Numbering Authority (CNA) notified Replicated on 23 January 2025 that the CVE was still in Reserved But Public (RBP) status. Upon discovering the oversight in updating the status to published with the CNA, Replicated submitted the updated report on the same day, 23 January 2025. |
| Improper buffer restrictions in some Intel(R) Graphics software may allow an authenticated user to potentially enable escalation of privilege via local access. |
| A flaw was found in Foreman/Red Hat Satellite. Improper file permissions allow low-privileged OS users to monitor and access temporary files under /var/tmp, exposing sensitive command outputs, such as /etc/shadow. This issue can lead to information disclosure and privilege escalation if exploited effectively. |
| SAP GUI for Windows & RFC service credentials are incorrectly stored in the memory of the program allowing an unauthenticated attacker to access information within systems, resulting in privilege escalation. On successful exploitation, this could result in disclosure of highly sensitive information. This has no impact on integrity, and availability. |
| Infinix devices contain a pre-loaded "com.transsion.agingfunction" application, that exposes an unsecured broadcast receiver. An attacker can communicate with the receiver and force the device to perform a factory reset without any Android system permissions.
After multiple attempts to contact the vendor we did not receive any answer. We suppose this issue affects all Infinix Mobile devices. |
| Cross Application Scripting vulnerability in Vercom S.A. Redlink SDK in specific situations allows local code injection and to manipulate the view of a vulnerable application.This issue affects Redlink SDK versions through 1.13. |
| An issue in Beijing Baidu Netcom Science & Technology Co Ltd Baidu Lite app (iOS version) 6.40.0 allows attackers to access user information via supplying a crafted link. |
| An issue in Hangzhou Bobo Technology Co Ltd UU Game Booster iOS 10.6.13 allows attackers to access sensitive user information via supplying a crafted link. |
| An issue in KuGou Technology Co., Ltd KuGou Concept iOS 4.0.61 allows attackers to access sensitive user information via supplying a crafted link. |
| An issue in Guangzhou Polar Future Culture Technology Co., Ltd University Search iOS 2.27.0 allows attackers to access sensitive user information via supplying a crafted link. |
| An issue in KuGou Technology CO. LTD KuGou Music iOS v20.0.0 allows attackers to access sensitive user information via supplying a crafted link. |
| An issue in Xiamen Meitu Technology Co., Ltd. BeautyCam iOS v12.3.60 allows attackers to access sensitive user information via supplying a crafted link. |
| When RKE provisions a cluster, it stores the cluster state in a configmap called `full-cluster-state` inside the `kube-system` namespace of the cluster itself. The information available in there allows non-admin users to escalate to admin. |