| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
|
In AutomationDirect C-MORE EA9 HMI,
credentials used by the platform are stored as plain text on the device.
|
| An issue in Debezium Community debezium-ui v.2.5 allows a local attacker to execute arbitrary code via the refresh page function. |
| User passwords are decrypted and stored on memory before any user logged in. Those decrypted passwords can be retrieved from the coredump file. As for the details of affected product names, model numbers, and versions, refer to the information provided by the respective vendors listed under [References]. |
| BAS-IP AV-01D, AV-01MD, AV-01MFD, AV-01ED, AV-01KD, AV-01BD, AV-01KBD, AV-02D, AV-02IDE, AV-02IDR, AV-02IPD, AV-02FDE, AV-02FDR, AV-03D, AV-03BD, AV-04AFD, AV-04ASD, AV-04FD, AV-04SD, AV-05FD, AV-05SD, AA-07BD, AA-07BDI, BA-04BD, BA-04MD, BA-08BD, BA-08MD, BA-12BD, BA-12MD, CR-02BD before firmware v3.9.2 allows authenticated attackers to read SIP account passwords via a crafted GET request. |
| A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA1) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA1) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA1) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA1) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA1) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA1) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA1) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA1) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA1) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA1) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA1) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA1) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA1) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA1) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA1) (All versions). Affected devices store user passwords in plaintext without proper protection. This could allow a physical attacker to retrieve them from the embedded storage ICs. |
| An issue in Solar-Log 1000 before v2.8.2 and build 52-23.04.2013 was discovered to store plaintext passwords in the export.html, email.html, and sms.html files -- fixed with 3.0.0-60 11.10.2013 for SL 200, 500, 1000 / not existing for SL 250, 300, 1200, 2000, SL 50 Gateway, SL Base. |
| Draytek devices Vigor 165/166 prior to v4.2.6 , Vigor 2620/LTE200 prior to v3.9.8.8, Vigor 2860/2925 prior to v3.9.7, Vigor 2862/2926 prior to v3.9.9.4, Vigor 2133/2762/2832 prior to v3.9.8, Vigor 2135/2765/2766 prior to v4.4.5.1, Vigor 2865/2866/2927 prior to v4.4.5.3, Vigor 2962/3910 prior to v4.3.2.7, Vigor 3912 prior to v4.3.5.2, and Vigor 2925 up to v3.9.6 were discovered to store passwords in plaintext. |
| HCL Workload Scheduler stores user credentials in plain text which can be read by a local user. |
| This vulnerability exists in Digisol Router (DG-GR1321: Hardware version 3.7L; Firmware version : v3.2.02) due to lack of encryption or hashing in storing of passwords within the router's firmware/ database. An attacker with physical access could exploit this by extracting the firmware and reverse engineer the binary data to access the plaintext passwords on the vulnerable system.
Successful exploitation of this vulnerability could allow the attacker to gain unauthorized access to the targeted system. |
| Smart-tab Android app installed April 2023 or earlier contains an issue with plaintext storage of a password. If this vulnerability is exploited, an attacker with physical access to the device may retrieve the credential information and spoof the device to access the related external service. |
| Certain hybrid DVR models ((HBF-09KD and HBF-16NK)) from Hunt Electronic have an Exposure of Sensitive Information vulnerability, allowing unauthenticated remote attackers to directly access a system configuration file and obtain plaintext administrator credentials. |
| Multiple wireless router models from Sapido have an Exposure of Sensitive Information vulnerability, allowing unauthenticated remote attackers to directly access a system configuration file and obtain plaintext administrator credentials.
The affected models are out of support; replacing the device is recommended. |
| A Plaintext Storage of a Password vulnerability in SUSE exposes the credentials for the HTTP proxy in the log files. This issue affects Container suse/manager/4.3/proxy-httpd:4.3.16.9.67.1: from ? before 4.3.33-150400.3.55.2; Container suse/manager/5.0/x86_64/proxy-httpd:5.0.5.7.23.1: from ? before 5.0.14-150600.4.17.1; Container suse/manager/5.0/x86_64/server:5.0.5.7.30.1: from ? before 5.0.14-150600.4.17.1; Image SLES15-SP4-Manager-Proxy-4-3-BYOS: from ? before 4.3.33-150400.3.55.2; Image SLES15-SP4-Manager-Proxy-4-3-BYOS-Azure: from ? before 4.3.33-150400.3.55.2; Image SLES15-SP4-Manager-Proxy-4-3-BYOS-EC2: from ? before 4.3.33-150400.3.55.2; Image SLES15-SP4-Manager-Proxy-4-3-BYOS-GCE: from ? before 4.3.33-150400.3.55.2; Image SLES15-SP4-Manager-Server-4-3-BYOS: from ? before 4.3.33-150400.3.55.2; Image SLES15-SP4-Manager-Server-4-3-BYOS-Azure: from ? before 4.3.33-150400.3.55.2; Image SLES15-SP4-Manager-Server-4-3-BYOS-EC2: from ? before 4.3.33-150400.3.55.2; Image SLES15-SP4-Manager-Server-4-3-BYOS-GCE: from ? before 4.3.33-150400.3.55.2; SUSE Manager Proxy Module 4.3: from ? before 4.3.33-150400.3.55.2; SUSE Manager Server Module 4.3: from ? before 4.3.33-150400.3.55.2. |
| WF2220 exposes endpoint /cgi-bin-igd/netcore_get.cgi that returns configuration of the device to unauthorized users. Returned configuration includes cleartext password.
The vendor was contacted early about this disclosure but did not respond in any way. |
| After gaining access to the firmware of a charging station, a file at <redacted> can be accessed to obtain default credentials that are the same across all Iocharger AC model EV chargers.
This issue affects Iocharger firmware for AC models before firmware version 25010801.
The issue is addressed by requiring a mandatory password change on first login, it is still recommended to change the password on older models.
Likelihood: Moderate – The attacker will first have to abuse a code execution or file inclusion vulnerability (for example by using <redacted>.sh) to gain access to the <redacted>.json file, or obtain a firmware dump of the charging station or obtain the firmware via other channels.
Impact: Critical – All chargers using Iocharger firmware for AC models started with the same initial password. For models with firmware version before 25010801 a password change was not mandatory. It is therefore very likely that this firmware password is still active on many chargers. These credentials could, once obtained, allow an attacker to log into many Iocharger charging station, and allow them to execute arbitrary commands via the System → Custom page.
CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, and requires high privileges (PR:H), there is no user interaction required (UI:N). The attack leads to a compromised of the confidentialy of the "super user" credentials of the device (VC:H/VI:N/VA:N), and can subsequently be used to full compromise and other devices (SC:H/SI:H/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). |
| A vulnerability exists in the VideONet product included in the listed System 800xA versions, where VideONet is used.
An attacker who successfully exploited the vulnerability could, in the worst case scenario, stop or manipulate the video feed.
This issue affects System 800xA: 5.1.X; System 800xA: 6.0.3.X; System 800xA: 6.1.1.X; System 800xA: 6.2.X. |
| Coredump binaries in Toshiba printers have incorrect permissions. A local attacker can steal confidential information. As for the affected products/models/versions, see the reference URL. |
| Westermo EDW-100 devices through 2024-05-03 allow an unauthenticated user to download a configuration file containing a cleartext password. NOTE: this is a serial-to-Ethernet converter that should not be placed at the edge of the network. |
| A flaw was found in how Quay's database is stored in plain-text in mirror-registry on the jinja's config.yaml file. This flaw allows a malicious actor with access to this file to gain access to Quay's database. |
| A flaw was found in Quay, where Quay's database is stored in plain text in mirror-registry on Jinja's config.yaml file. This issue leaves the possibility of a malicious actor with access to this file to gain access to Quay's Redis instance. |