| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Flowise is a drag & drop user interface to build a customized large language model flow. Prior to August 2025 Cloud-Hosted Flowise, an authenticated vulnerability in Flowise Cloud allows any user on the free tier to access sensitive environment variables from other tenants via the Custom JavaScript Function node. This includes secrets such as OpenAI API keys, AWS credentials, Supabase tokens, and Google Cloud secrets — resulting in a full cross-tenant data exposure. This issue has been patched in the August 2025 Cloud-Hosted Flowise. |
| The target device exposes a service on a specific TCP port with a configured
endpoint. The access to that endpoint is granted using a Basic Authentication
method. The endpoint accepts also the PUT method and it is possible to
write files on the target device file system. Files are written as root.
Using Postman it is possible to perform a Directory Traversal attack
and write files into any location of the device file system. Similarly to the PUT method, it is possible to leverage the
same mechanism to read any file from the file system by using the GET
method. |
| A vulnerability, which was classified as problematic, was found in Tsinghua Unigroup Electronic Archives System 3.2.210802(62532). This affects an unknown part of the file /Logs/Annals/downLoad.html. The manipulation of the argument path leads to information disclosure. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. |
| A vulnerability was determined in ketr JEPaaS up to 7.2.8. Affected by this vulnerability is an unknown functionality of the file /je/load. This manipulation of the argument Authorization causes improper authorization. The attack is possible to be carried out remotely. The exploit has been publicly disclosed and may be utilized. |
| Ratify is a verification engine as a binary executable and on Kubernetes which enables verification of artifact security metadata and admits for deployment only those that comply with policies the user creates. In a Kubernetes environment, Ratify can be configured to authenticate to a private Azure Container Registry (ACR). The Azure workload identity and Azure managed identity authentication providers are configured in this setup. Users that configure a private ACR to be used with the Azure authentication providers may be impacted by a vulnerability that exists in versions prior to 1.2.3 and 1.3.2. Both Azure authentication providers attempt to exchange an Entra ID (EID) token for an ACR refresh token. However, Ratify’s Azure authentication providers did not verify that the target registry is an ACR. This could have led to the EID token being presented to a non-ACR registry during token exchange. EID tokens with ACR access can potentially be extracted and abused if a user workload contains an image reference to a malicious registry. As of versions 1.2.3 and 1.3.2, the Azure workload identity and Azure managed identity authentication providers are updated to add new validation prior to EID token exchange. Validation relies upon registry domain validation against a pre-configured list of well-known ACR endpoints. EID token exchange will be executed only if at least one of the configured well-known domain suffixes (wildcard support included) matches the registry domain of the image reference. |
| scratch-coding-hut.github.io is the website for Coding Hut. In 1.0-beta3 and earlier, the login link can be used to login to any account by changing the username in the username field. |
| SummaryA user with administrator rights can change the configuration of the mautic application and extract secrets that are not normally available.
ImpactAn administrator who usually does not have access to certain parameters, such as database credentials, can disclose them. |
| A vulnerability was found in eGauge EG3000 Energy Monitor 3.6.3. It has been classified as problematic. This affects an unknown part of the component Setting Handler. The manipulation leads to missing authentication. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| A vulnerability was found in Papendorf SOL Connect Center 3.3.0.0 and classified as problematic. Affected by this issue is some unknown functionality of the component Web Interface. The manipulation leads to missing authentication. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| Incorrect access control in Jantent v1.1 allows attackers to bypass authentication and access sensitive APIs without a token. |
| Incorrect access control in radar v1.0.8 allows attackers to bypass authentication and access sensitive APIs without a token. |
| Incorrect access control in dts-shop v0.0.1-SNAPSHOT allows attackers to bypass authentication via sending a crafted payload to /admin/auth/index. |
| Broken access control vulnerability in Geovision GV-ASWeb with version v6.1.0.0 or less. This vulnerability allows low privilege users perform actions that they aren't authorized to, which can be leveraged to escalate privileges, create, modify or delete accounts. |
| An ownership verification issue in the Virtual Desktop preview page in the Research and Engineering Studio (RES) on AWS before version 2025.09 may allow an authenticated remote user to view another user's active desktop session metadata, including periodical desktop preview screenshots.
To mitigate this issue, users should upgrade to version 2025.09 or above. |
| linjiashop <=0.9 is vulnerable to Incorrect Access Control. When using the default-generated JWT authentication, attackers can bypass the authentication and retrieve the encrypted "password" and "salt". The password can then be obtained through brute-force cracking. |
| A "Privilege boundary violation" vulnerability is identified affecting multiple Radiometer Products. Exploitation of this vulnerability gives a user with physical access to the analyzer, the possibility to gain unauthorized access to functionalities outside the restricted environment. The vulnerability is due to weakness in the design of access control implementation in application software.
Other related CVE's are CVE-2025-14096 & CVE-2025-14097.
Affected customers have been informed about this vulnerability. This CVE is being published to provide transparency.
Required configuration for Exposure:
Physical access to the analyzer is needed.
Temporary work Around:
Only authorized people can physically access the analyzer.
Permanent solution:
Local Radiometer representatives will contact all affected customers to discuss a permanent solution.
Exploit Status:
Researchers have provided working proof-of-concept. Radiometer is not aware of any publicly available exploit at the time of publication. Note:
CVSS score 6.8 when underlying OS is Windows 7 or Windows XP Operating systems and CVSS score 5.7 when underlying OS is Windows 8 or Windows 10 operating systems. |
| A lack of session validation in the web API component of Shenzhen Zhibotong Electronics ZBT WE2001 23.09.27 allows remote unauthenticated attackers to access administrative information-retrieval functions intended for authenticated users. By invoking "get_*" operations, attackers can obtain device configuration data, including plaintext credentials, without authentication or an existing session. |
| In Tenable Security Center versions prior to 6.7.0, an improper access control vulnerability exists where an authenticated user could access areas outside of their authorized scope. |
| If LDAP settings are accessed, authentication could be redirected to another server, potentially exposing credentials. This requires admin access and an active LDAP setup. |