| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| A low privileged remote attacker can corrupt the webserver users storage on the device by setting a sequence of unsupported characters which leads to deletion of all previously configured users and the creation of the default Administrator with a known default password. |
| In KDE Connect before 1.33.0 on Android, malicious device IDs (sent via broadcast UDP) could cause an application crash. |
| The SAP Approuter Node.js package version v16.7.1 and before is vulnerable to Authentication bypass. When trading an authorization code an attacker can steal the session of the victim by injecting malicious payload causing High impact on confidentiality and integrity of the application |
| A vulnerability has been identified in SIMATIC S7-1200 CPU 1211C AC/DC/Rly (6ES7211-1BE40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1211C DC/DC/DC (6ES7211-1AE40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1211C DC/DC/Rly (6ES7211-1HE40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1212C AC/DC/Rly (6ES7212-1BE40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1212C DC/DC/DC (6ES7212-1AE40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1212C DC/DC/Rly (6ES7212-1HE40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1212FC DC/DC/DC (6ES7212-1AF40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1212FC DC/DC/Rly (6ES7212-1HF40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1214C AC/DC/Rly (6ES7214-1BG40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1214C DC/DC/DC (6ES7214-1AG40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1214C DC/DC/Rly (6ES7214-1HG40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1214FC DC/DC/DC (6ES7214-1AF40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1214FC DC/DC/Rly (6ES7214-1HF40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1215C AC/DC/Rly (6ES7215-1BG40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1215C DC/DC/DC (6ES7215-1AG40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1215C DC/DC/Rly (6ES7215-1HG40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1215FC DC/DC/DC (6ES7215-1AF40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1215FC DC/DC/Rly (6ES7215-1HF40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1217C DC/DC/DC (6ES7217-1AG40-0XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1212 AC/DC/RLY (6AG1212-1BE40-2XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1212 AC/DC/RLY (6AG1212-1BE40-4XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1212 DC/DC/RLY (6AG1212-1HE40-2XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1212 DC/DC/RLY (6AG1212-1HE40-4XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1212C DC/DC/DC (6AG1212-1AE40-2XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1212C DC/DC/DC (6AG1212-1AE40-4XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1212C DC/DC/DC RAIL (6AG2212-1AE40-1XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214 AC/DC/RLY (6AG1214-1BG40-2XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214 AC/DC/RLY (6AG1214-1BG40-4XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214 AC/DC/RLY (6AG1214-1BG40-5XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214 DC/DC/DC (6AG1214-1AG40-2XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214 DC/DC/DC (6AG1214-1AG40-4XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214 DC/DC/DC (6AG1214-1AG40-5XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214 DC/DC/RLY (6AG1214-1HG40-2XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214 DC/DC/RLY (6AG1214-1HG40-4XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214 DC/DC/RLY (6AG1214-1HG40-5XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214C DC/DC/DC RAIL (6AG2214-1AG40-1XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214FC DC/DC/DC (6AG1214-1AF40-5XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214FC DC/DC/RLY (6AG1214-1HF40-5XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215 AC/DC/RLY (6AG1215-1BG40-2XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215 AC/DC/RLY (6AG1215-1BG40-4XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215 AC/DC/RLY (6AG1215-1BG40-5XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215 DC/DC/DC (6AG1215-1AG40-2XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215 DC/DC/DC (6AG1215-1AG40-4XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215 DC/DC/RLY (6AG1215-1HG40-2XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215 DC/DC/RLY (6AG1215-1HG40-4XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215 DC/DC/RLY (6AG1215-1HG40-5XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215C DC/DC/DC (6AG1215-1AG40-5XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215FC DC/DC/DC (6AG1215-1AF40-5XB0) (All versions < V4.7). Affected devices do not process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device. |
| Westermo WeOS 5 through 5.23.0 allows a reboot via a malformed ESP packet. |
| A denial-of-service security issue in the affected product. The security issue occurs when a malformed CIP forward open message is sent. This could result in a major nonrecoverable fault a restart is required to recover. |
| An integer underflow vulnerability in the Silicon Labs Z-Wave Protocol Controller can lead to out of bounds memory reads. |
| 51l3nc3, member of the AXIS OS Bug Bounty Program, has found that the VAPIX API managedoverlayimages.cgi was vulnerable to a race condition attack allowing for an attacker to block access to the overlay configuration page in the web interface of the Axis device. This flaw can only be exploited after authenticating with an operator- or administrator-privileged service account. Axis has released patched AXIS OS versions for the highlighted flaw. Please refer to the Axis security advisory for more information and solution. |
| Nokia Single RAN baseband software versions earlier than 24R1-SR 2.1 MP contain a SOAP message input validation flaw, which in theory could potentially be used for causing resource exhaustion in the Single RAN baseband OAM service.
No practical exploit has been detected for this flaw. However, the issue has been corrected starting from release 24R1-SR 2.1 MP by adding sufficient input validation for received SOAP requests, effectively mitigating the reported issue. |
| Improper Validation of Specified Quantity in Input vulnerability in Mitsubishi Electric CNC Series allows a remote unauthenticated attacker to cause Denial of Service (DoS) condition on the product by sending specially crafted packets to TCP port 683, causing an emergency stop. |
| A memory corruption vulnerability exists in the affected products when parsing DFT files. Local threat actors can exploit this issue to disclose information and to execute arbitrary code. To exploit this vulnerability a legitimate user must open a malicious DFT file. |
| A denial of service vulnerability was found in the 389-ds-base LDAP server. This issue may allow an authenticated user to cause a server denial of service while attempting to log in with a user with a malformed hash in their password. |
| The NVMe driver queue processing is vulernable to guest-induced infinite loops. |
| A guest can trigger an infinite loop in the hda audio driver. |
| Sequence of processor instructions leads to unexpected behavior in the Intel(R) DSA V1.0 for some Intel(R) Xeon(R) Processors may allow an authenticated user to potentially enable denial of service via local access. |
| A key used in logging.json does not follow the least privilege principle by default and is exposed to local users in the Rapid7 Platform. This allows an attacker with local access to a machine with the logging.json file to use that key to authenticate to the platform with high privileges. This was fixed in the Rapid7 platform starting 3 April 2024 via the introduction of a restricted role and the removal of automatic API key generation on installation of an agent. |
|
A vulnerability was reported
in a system recovery bootloader that was part of the Lenovo preloaded Windows 7 and 8 operating systems from 2012 to 2014
that could allow a privileged attacker with local access to modify the boot manager and escalate privileges.
|
| Malformed BRID/HHIT records can cause `named` to terminate unexpectedly.
This issue affects BIND 9 versions 9.18.40 through 9.18.43, 9.20.13 through 9.20.17, 9.21.12 through 9.21.16, 9.18.40-S1 through 9.18.43-S1, and 9.20.13-S1 through 9.20.17-S1. |
| A Denial of Service (Dos) vulnerability in Nozomi Networks Guardian, caused by improper input validation in certain fields used in the Radius parsing functionality of our IDS, allows an unauthenticated attacker sending specially crafted malformed network packets to cause the IDS module to stop updating nodes, links, and assets.
Network traffic may not be analyzed until the IDS module is restarted. |
| A vulnerability in the “Network Interfaces” functionality of the web application of ctrlX OS allows a remote authenticated (low-privileged) attacker to manipulate the network configuration file via a crafted HTTP request. |