| An adjacent attacker without authentication can exploit this vulnerability to retrieve a set of user-privileged credentials. These credentials are present during the firmware upgrade procedure. |
| Cleartext Transmission of Sensitive Information vulnerability in Crestron Automate VX allows Sniffing Network Traffic.
The device allows Web UI and API access over non-secure network ports which exposes sensitive information such as user passwords.
This issue affects Automate VX: from 5.6.8161.21536 through 6.4.0.49. |
| YugabyteDB diagnostic information was transmitted over HTTP, which could expose sensitive data during transmission |
| Cleartext Storage of Sensitive Information Vulnerability in GX Works2 all versions allows an attacker to disclose credential information stored in plaintext from project files. As a result, the attacker may be able to open project files protected by user authentication using disclosed credential information, and obtain or modify project information. |
| Insufficient encryption vulnerability in the mobile application (com.transsion.aivoiceassistant) may lead to the risk of sensitive information leakage. |
| Encryption is missing on the configuration interface for Growatt ShineLan-X and MIC 3300TL-X. This allows an attacker with access to the network to intercept and potentially manipulate communication requests between the inverter and its cloud endpoint. |
| Arctera/Veritas Data Insight before 7.1.2 can send cleartext credentials when configured to use HTTP Basic Authentication to a Dell Isilon OneFS server. |
| NVIDIA Delegated Licensing Service for all appliance platforms contains a vulnerability where an User/Attacker may cause an authorized action. A successful exploit of this vulnerability may lead to information disclosure. |
| Secure flag not set and SameSIte was set to Lax in the Foreseer Reporting Software (FRS). Absence of this secure flag could lead into the session cookie being transmitted over unencrypted HTTP connections. This security issue has been resolved in the latest version of FRS v1.5.100. |
| This vulnerability exists in ZKTeco WL20 due to storage of admin and user credentials without encryption in the device firmware. An attacker with physical access could exploit this vulnerability by extracting the firmware and reverse engineer the binary data to access the unencrypted credentials stored in the firmware of targeted device. |
| Lack of sensitive data encryption in CapillaryScope v2.5.0 of Capillary io, which stores both the proxy credentials and the JWT session token in plain text within different registry keys on the Windows operating system. Any authenticated local user with read access to the registry can extract these sensitive values. |
| Insufficiently Protected Credentials in the Mail Server Configuration in GoPhish v0.12.1 allows an attacker to access cleartext passwords for the configured IMAP and SMTP servers. |
| Medtronic MyCareLink Patient Monitor uses an unencrypted filesystem on internal storage, which allows an attacker with physical access to read and modify files.
This issue affects MyCareLink Patient Monitor models 24950 and 24952: before June 25, 2025 |
| The Temporal api-go library prior to version 1.44.1 did not send `update response` information to Data Converter when the proxy package within the api-go module was used in a gRPC proxy prior to transmission. This resulted in information contained within the `update response` field not having Data Converter transformations (e.g. encryption) applied. This is an issue only when using the UpdateWorkflowExecution APIs (released on 13th January 2025) with a proxy leveraging the api-go library before version 1.44.1.
Other data fields were correctly sent to Data Converter. This issue does not impact the Data Converter server. Data was encrypted in transit. Temporal Cloud services are not impacted. |
| When using domain users as BRAIN2 users, communication with Active Directory services is unencrypted. This can lead to the interception of authentication data and compromise confidentiality. |
| A Credential Exposure Vulnerability exists in the above-mentioned product and version. The vulnerability is due to using HTTP resulting in credentials being sent in clear text. |
| CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists that could result in the exposure
of data when network traffic is being sniffed by an attacker. |
| All WorkExaminer Professional traffic between monitoring client, console and server is transmitted as plain text. This allows an attacker with access to the network to read the transmitted sensitive data. An attacker can also freely modify the data on the wire. The monitoring clients transmit their data to the server using the unencrypted FTP. Clients connect to the FTP server on port 12304 and transmit the data unencrypted. In addition, all traffic between the console client and the server at port 12306 is unencrypted. |
| This vulnerability exists in Philips lighting devices due to storage of Wi-Fi credentials in plain text within the device firmware. An attacker with physical access could exploit this by extracting the firmware and analyzing the binary data to obtain the plaintext Wi-Fi credentials stored on the vulnerable device.
Successful exploitation of this vulnerability could allow an attacker to gain unauthorized access to the Wi-Fi network to which vulnerable device is connected. |
| Using the AES-128-CCM algorithm for IPSec on certain Palo Alto Networks PAN-OS® firewalls (PA-7500, PA-5400, PA-5400f, PA-3400, PA-1600, PA-1400, and PA-400 Series) leads to unencrypted data transfer to devices that are connected to the PAN-OS firewall through IPSec.
This issue does not affect Cloud NGFWs, Prisma® Access instances, or PAN-OS VM-Series firewalls.
NOTE: The AES-128-CCM encryption algorithm is not recommended for use. |