Search Results (3860 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2022-50980 2 Avibia, Innomic 20 Avibialine Avle1 Hd, Avibialine Avle2 Hd, Avibialine Avle4 Hd and 17 more 2026-04-15 6.5 Medium
A unauthenticated adjacent attacker could potentially disrupt operations by switching between multiple configuration presets via CAN.
CVE-2022-50979 2 Avibia, Innomic 20 Avibialine Avle1 Hd, Avibialine Avle2 Hd, Avibialine Avle4 Hd and 17 more 2026-04-15 6.5 Medium
An unauthenticated adjacent attacker could potentially disrupt operations by switching between multiple configuration presets via Modbus (RS485).
CVE-2025-3232 1 Mitsubishielectric 1 Smartrtu 2026-04-15 7.5 High
A remote unauthenticated attacker may be able to bypass authentication by utilizing a specific API route to execute arbitrary OS commands.
CVE-2023-6215 1 Hp 2 Hp, Sure Start Ifd Protection 2026-04-15 N/A
A potential security vulnerability has been identified in HP Sure Start’s protection of the Intel Flash Descriptor in certain HP PC products, which might allow security bypass, arbitrary code execution, loss of integrity or confidentiality, or denial of service. HP is releasing BIOS updates to mitigate the potential vulnerability.
CVE-2025-27256 2026-04-15 8.3 High
Missing Authentication for Critical Function vulnerability in GE Vernova Enervista UR Setup application allows Authentication Bypass due to a missing SSH server authentication. Since the client connection is not authenticated, an attacker may perform a man-in-the-middle attack on the network.
CVE-2022-50978 2 Avibia, Innomic 20 Avibialine Avle1 Hd, Avibialine Avle2 Hd, Avibialine Avle4 Hd and 17 more 2026-04-15 7.5 High
An unauthenticated remote attacker could potentially disrupt operations by switching between multiple configuration presets via Modbus (TCP).
CVE-2025-27214 2026-04-15 9.8 Critical
A Missing Authentication for Critical Function vulnerability in the UniFi Connect EV Station Pro may allow a malicious actor with physical or adjacent access to perform an unauthorized factory reset. Affected Products: UniFi Connect EV Station Pro (Version 1.5.18 and earlier) Mitigation: Update UniFi Connect EV Station Pro to Version 1.5.27 or later
CVE-2025-25265 2026-04-15 4.9 Medium
A web application for configuring the controller is accessible at a specific path. It contains an endpoint that allows a high privileged remote attacker to read files from the system’s file structure.
CVE-2022-50977 2 Avibia, Innomic 20 Avibialine Avle1 Hd, Avibialine Avle2 Hd, Avibialine Avle4 Hd and 17 more 2026-04-15 7.5 High
An unauthenticated remote attacker could potentially disrupt operations by switching between multiple configuration presets via HTTP.
CVE-2025-2407 2026-04-15 N/A
Missing Authentication & Authorization in Web-API in Mobatime AMX MTAPI v6 on IIS allows adversaries to unrestricted access via the network. The vulnerability is fixed in Version 1.5.
CVE-2025-1701 2026-04-15 N/A
CVE-2025-1701 is a high-severity vulnerability in the MIM Admin service. An attacker could exploit this vulnerability by sending a specially crafted request over the RMI interface to execute arbitrary code with the privileges of the MIM Admin service. The RMI interface is only accessible locally (listening on 127.0.0.1), limiting the attack vector to the local machine. This means that in a properly configured hospital environment, an attacker must have already compromised the network and additionally compromised the system where the MIM Admin service is running. From there, attackers with sufficient knowledge of MIM's implementation, library usage, and functionality with access to extend the MIM RMI library could force the MIM Admin service to run commands on the local machine with its privileges. Users of MIM Software products exposed via RDP or multi-user application virtualization system should take note that the system being exposed is the environment hosting the virtualized MIM client. This issue affects MIM Admin Service: before 7.2.13, 7.3.8, 7.4.3
CVE-2025-24924 2026-04-15 9.8 Critical
Certain functionality within GMOD Apollo does not require authentication when passed with an administrative username
CVE-2022-43110 1 Voltronicpower 1 Viewpower 2026-04-15 9.8 Critical
Voltronic Power ViewPower through 1.04-21353 and PowerShield Netguard before 1.04-23292 allows a remote attacker to configure the system via an unspecified web interface. An unauthenticated remote attacker can make changes to the system including: changing the web interface admin password, view/change system configuration, enumerate connected UPS devices and shut down connected UPS devices. This extends to being able to configure operating system commands that should run if the system detects a connected UPS shutting down.
CVE-2025-14058 1 Lenovo 31 Idea Tab Pro Tb373fu, Idea Tab Tb336fu, Legion Tab Tb320fc and 28 more 2026-04-15 3.2 Low
A potential missing authentication vulnerability was reported in some Lenovo Tablets that could allow an unauthorized user with physical access to modify Control Center settings if the device is locked when the "Allow Control Center access when locked" option is disabled.
CVE-2020-37146 1 Ace Security 1 Aptina Ar0130 960p 1.3mp Camera 2026-04-15 7.5 High
ACE Security WiP-90113 HD Camera contains a configuration disclosure vulnerability that allows unauthenticated attackers to retrieve sensitive configuration files. Attackers can access the camera's configuration backup by sending a GET request to the /config_backup.bin endpoint, exposing credentials and system settings.
CVE-2025-5871 2026-04-15 5.3 Medium
A vulnerability was found in Papendorf SOL Connect Center 3.3.0.0 and classified as problematic. Affected by this issue is some unknown functionality of the component Web Interface. The manipulation leads to missing authentication. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2021-26278 2026-04-15 6.3 Medium
The wifi module exposes the interface and has improper permission control, leaking sensitive information about the device.
CVE-2025-5876 2026-04-15 5.3 Medium
A vulnerability classified as problematic was found in Lucky LM-520-SC, LM-520-FSC and LM-520-FSC-SAM up to 20250321. Affected by this vulnerability is an unknown functionality. The manipulation leads to missing authentication. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2025-30410 1 Acronis 3 Acronis Cyber Protect 15, Acronis Cyber Protect 16, Cyber Protect Cloud Agent 2026-04-15 N/A
Sensitive data disclosure and manipulation due to missing authentication. The following products are affected: Acronis Cyber Protect Cloud Agent (Linux, macOS, Windows) before build 39870, Acronis Cyber Protect 16 (Linux, macOS, Windows) before build 39938, Acronis Cyber Protect 15 (Linux, macOS, Windows) before build 41800.
CVE-2025-10267 1 Newtype Infortech 1 Nup Portal 2026-04-15 5.3 Medium
NUP Portal developed by NewType Infortech has a Missing Authentication vulnerability, allowing unauthenticated remote attackers to directly upload files. If the attacker manages to bypass the file extension restrictions, they could upload a webshell and execute it on the server side.